Cellular Glass (Foam Glass) Board

Closed-cell foam glass board for cryogenic lines, load-bearing roofs and cold-store floors. Zero water uptake.

Cellular Glass (Foam Glass) Board

Specifications

HS code701690
StandardASTM C552 / EN 13167
Density140-160 kg/m3
Thermal conductivityλ 0.050-0.056 W/mK at 10 °C
Compressive strength0.7-1.0 MPa
Service temperature-268 to +480 °C
Reaction to fireA1 (EN 13501-1)
PackingCartons or film-wrapped pallets, about 60-65 m3 per 40HQ
Typical originsChina, Belgium, Czechia

What sets the price

  • Styrene, polyol and MDI raw material cost for XPS, EPS and PU/PIR
  • Bitumen, SBS/APP polymer and PVC resin prices for membranes
  • Mill energy cost and steel coil price for mineral wool and sandwich panels
  • Ocean freight per m3, since most insulation lots cube out before they weigh out